Windrose truck and a 20 ft chassis with Windrose Power

Power

The truck's platform, in a 20 ft container.

Shared with the truck

Never grid-connected: it supplies off-grid 400 V AC to chargers and site loads (V2L, not V2G) and never feeds power back to the grid.

How it works

Wind Farm
⚡ Charges
Power
Ships to site
Site
Its own 400 V supply:
truck chargers and site loads

Deep Dive

Packs, Distribution, Control and Cooling

Each string in the container is one truck's battery system: four packs, one power distribution unit and one vehicle controller, with the same part numbers. Two European CO₂ heat pump units, one per string, cool and heat all eight packs. The pack, PDU and controller specifications below are the truck's, and each one explains a design choice in the container.

1 Battery packs: the truck pack, unmodified

2101100

176.3 kWh
Per pack
766 V
Nominal · 238 cells in series
1C
Charge and discharge rate
4,500
Cycles at 25 °C to 70 % health

The pack is the cell-to-pack LFP unit from the Windrose E700: cells, battery monitor, high-voltage parts and a liquid cold plate in one IP67 enclosure. Four of them make one truck's 705 kWh; four of them make one string here.

SpecificationValueWhy it matters in the container
CellLFP prismatic, 230 Ah, 3.22 V nominal, 2.5–3.65 V, 4.2 kg, 180 Wh/kgThe same cell as the truck, so the container draws on the truck's cell supply and test record instead of a second qualification.
Topology1P238S: 238 cells in series, no parallel groupsEvery cell carries the pack current and is measured on its own. Paralleling happens at string level (four packs) and on the AC side (two strings), never inside a pack.
Operating voltage595–868.7 V DC (766.4 V nominal)Sets the window for everything downstream: PDU, cables, the thermal-unit compressor and the PCS DC input all come from, or are chosen for, this range.
Energy and mass176.3 kWh · 1,146 kg · 155 Wh/kgEight packs are 9.2 t and 1.41 MWh in a standard-height 20 ft box. On a 20 ft container chassis the overall height is about 3.92 m, so no low-loader is needed.
Cycle life4,500 full cycles at 25 °C to 70 % state of health (cell: over 6,000)Stationary duty is daily cycling. 4,500 cycles is more than twelve years at one full cycle per day, provided the cells are kept at the rated temperature.
TemperatureCell charge 0–60 °C, discharge −30–65 °C · pack thermal window −30–60 °CLFP cannot be charged below 0 °C and ages faster when hot. This is why the container carries at least 48 kW of cooling and 80 kW of heating.
Inside the packMain-negative contactor, fuse, current shunt, HVIL, cold plate, IP67Each pack can be unplugged and exchanged on its own. Precharge, the main-positive contactor and insulation monitoring are not duplicated eight times; they live once per string in the PDU.
Approvals heldUN 38.3 (transport) · UN ECE R100.03 (vehicle battery safety)Thermal shock and cycling, external short circuit, overcharge, over-discharge, over-temperature, vibration, mechanical shock and fire resistance are already tested at pack level. Those reports are the starting evidence for the container's EU Battery Regulation file.

2 Power distribution unit: one truck PDU per string

2104100外壳与接口 · Shell3703100

600 A
Main contactor
100 Ω
Precharge resistor
6 kW
24 V DC-DC converter
6
Pack inputs · 4 used

The PDU is the truck's high-voltage junction box. In the container, as in the truck, each PDU joins four packs into one bus, switches that bus, watches its insulation and makes the 24 V that runs everything else. Its drive outputs, which feed the axles in the truck, feed the off-grid PCS, which supplies 400 V three-phase AC. Its two fast-charge paths are hard-wired to a one-way rectifier for charging.

SpecificationValueWhy it matters in the container
Pack inputsSix pack positions, each with its own positive and negative cable; LFP uses four, in the truck and in the containerEach pack has its own path to the bus, so a pack can be unplugged and exchanged on its own.
Main contactor600 A main-positive contactorThe one switch that makes the string live or dead. The packs' own contactors are main-negative only, so both poles open on shutdown.
Precharge100 Ω resistor; main positive closes once the voltage difference stays below 15 V for 100 msThe PCS DC link is a large capacitor. Charging it through the resistor first keeps the inrush off the contactor contacts, which is what lets them reach their rated life.
Insulation monitoringContinuous insulation monitor on the high-voltage busThe bus is a floating 595–869 V system. A drop in insulation to the container body is detected and reported before it becomes a hazard, the same way it is on the truck chassis.
24 V supply24 V / 6 kW DC-DC converter fed from the pack bus; two 12 V batteries for wake-upControllers, pumps and the thermal-unit fans run from the battery itself. The container needs no external auxiliary supply.
Live and dead zonesPacks to PDU inputs: always live · after the PDU contactors: dead on shutdownThe service rule is the truck's: pulling the low-voltage service disconnect opens the contactors, while the pack interiors and the pack output connectors stay live.
CoolingLiquid-cooled from the pack loopContactors and the DC-DC converter run at coolant temperature, not at the air temperature inside a closed steel box.
Shutdown and faultsNormal: PCS ramps below 5 A, then the contactors open in reverse order · On a fault: the PDU opens the high voltage at once · The design includes an external emergency stop with visible disconnectionOpening a contactor under load shortens its life. The sequence protects it; the fault path ignores the sequence.

Without the truck PDU, the PCS would need its own precharge circuit, a DC combiner cabinet, a separate 24 V supply and a separate high-voltage feed for the thermal units.

3 Vehicle controller: same hardware, same firmware, storage mode

2108100

2
Controllers · one per string
≤ 10 V
Pack spread before closing
< 15 V
Precharge done
< 5 A
Current before opening

The controller is the truck's vehicle controller with one configuration word changed. Each controller talks to its four pack monitors over CAN, drives its PDU, controls its heat pump unit over CAN, tells the PCS how much current it may draw and sets the rectifier's charging current.

  1. WakeThe controller wakes the four pack monitors from the 24 V batteries and runs its self-test.
  2. Close packsPack main-negative contactors close from the highest pack voltage to the lowest, only while the packs are within 10 V of each other.
  3. PrechargeThe PDU charges the PCS DC link through 100 Ω until the difference stays below 15 V for 100 ms.
  4. Main positiveThe 600 A contactor closes. The string is live.
  5. AuxiliariesThermal units, the DC-DC converter and the insulation monitor are powered.
  6. ReleaseThe controller releases the PCS current limit and the rectifier's charging current. Charging or discharging can start.
  7. ShutdownThe PCS brings the current to zero. Below 5 A the controller opens the contactors in reverse order. On a fault the PDU opens at once.
SpecificationValueWhy it matters in the container
Hardware and softwareTruck vehicle controller, unchanged; storage mode selected by configurationThe contactor sequencing, insulation check, thermal-management control and fault diagnosis are the functions already in service on the truck. One spare part and one diagnostic tool cover both products.
Battery dataCell voltages, temperatures, state of charge and state of health from each pack's own monitor over CANThe pack monitor is the source of truth for the cells; the controller supervises four of them and sets the limits. The EU Battery Regulation's read-only state-of-health access (Art. 14) will be served from here.
Interface to the PCSCharge and discharge current limits, released after power-up and withdrawn before shutdownThe PCS never decides on its own how hard to drive the battery. The limits follow cell temperature and state of charge, exactly as they do for the truck's charger.
StringsTwo strings, one controller each; strings are paralleled only on the AC sideA fault on one string takes 705 kWh offline, not 1.41 MWh. No DC paralleling means no circulating current between strings at different states of charge.
Service disconnectThe truck's low-voltage service disconnect plug, one per controllerPulling it de-energises the contactor coils and the HVIL, so the contactors open. For work: pull it, keep plug and key with you, disconnect the 24 V negative, wait 10 minutes and prove dead, as on the truck.

4 Cooling and heating: why the heat pumps decide the power

21270131311110

20–35 °C
Cell window for the full 1C
< 5 °C
Heat only, no charging
≥ 80 kW
Heating from −20 °C
42 °C
Max cell at 1C, 25 °C ambient

The packs reach their full rate only inside a cell temperature window. The battery monitor's charge map allows the full 1C between 20 and 35 °C, reduces it at 5–15 °C and at 40–45 °C, and allows no charging at all below 5 °C. The heat pump units keep the packs in that window, so they are sized for 1C on all eight packs and run from the battery bus.

SpecificationValueWhy it matters in the container
Cooling needAt least 48 kW for eight packs at 1C and 40 °C ambient: 2 units × ≥ 24 kWOne unit per string. If one unit fails, the other string keeps running.
Heating needAt least 80 kW from −20 °C for eight packs: 2 units × ≥ 40 kWBelow 5 °C the packs can only be heated. The heat pumps bring them into the charge window.
Heat pump unitEuropean CO₂ (R744) heat pump unit, one per string; powered from the battery bus, HV DC 595–869 V; controlled over CAN by the VDCU; supplier not yet selectedThe EU F-gas Regulation (EU) 2024/573, Annex IV point 7, bans the truck unit's refrigerant in chillers from 2027. CO₂ has a GWP of 1 and is not flammable. Powered from the battery bus, cooling keeps running during an emergency stop.
Hot-weather proofTruck test, 20–80 % at 1C: 38.5 min with max cell 42 °C at 25 °C ambient; 48 min with max cell 45 °C at 45 °C ambientThe same cold plate held the cells inside the window at full rate in the truck test. Each container unit is specified for at least 24 kW per string at 40 °C ambient, for the same 1C on the same packs.
Loop layoutPer pack: DN20 supply and return · per column: DN25 riser · roof header DN32 · 5 L + 5 L expansion tank · truck drain valve at the lowest point · coolant about 65–70 L (estimate)The header and risers give every pack the same flow path so no pack runs warmer than its neighbours.
What is cooledEvery pack's cold plate, then the two PDUs, on one loopOne coolant, one set of pumps, one expansion tank. The electronics never see the air temperature inside the box.
Cycle life link4,500 cycles is rated at 25 °CThe warranty-relevant life figure assumes the thermal system does its job. Cooling is not an accessory; it is what makes the cycle rating real.

= What is shared with the truck, and what changes

PartOn the E700In the containerWhat changes
LFP battery pack210110048Nothing. Same part, same approvals; racked two columns by four layers instead of under a frame.
Power distribution unit2104100外壳与接口 · Shell12Nothing inside: four packs per PDU, as in the truck. Discharge uses the PDU drive outputs to the off-grid PCS. The fast-charge paths are hard-wired to a one-way rectifier. No CCS2 inlet.
Vehicle controller210810012One configuration word: storage mode. Hardware and firmware unchanged; one controller per string, as in the truck.
Battery thermal unit22Replaced: two European CO₂ (R744) heat pump units, one per string, instead of the truck units. Supplier not yet selected.
Expansion tank131111011Nothing; mounted at the highest point of the return line.
High- and low-voltage harnesses——Same cable and connector designs, cut to container lengths and held by the truck's high-voltage clamps and brackets instead of a cable tray.
24 V batteries370310022Nothing; two 12 V in series, charged by the PDU.
Low-voltage service disconnect12The truck's plug, one per vehicle controller.
Drain valve, battery bracket and cables, nameplate——Truck parts, used as they are.
New for the container——The container conversion, the welded pack frame and the safety systems of the Flemish BESS guideline (BVLAR v1.5): explosion vent, automatic extinguishing, smoke/flame and gas detection, external emergency stop, beacon, alarm transmission, backup power for the safety systems, coolant leak containment, CO2 extinguishers and a ventilated EI30 enclosure. Built in Antwerp, Belgium.

Rule behind the design: if the truck already has a part for the job, the container uses that part.

Battery Chemistry

LFP vs NCA: Why Chemistry Matters

Power uses LFP (Lithium Iron Phosphate) — the safest, longest-lived lithium-ion chemistry. Here's how it compares to NCA (Nickel Cobalt Aluminum), used in many stationary storage systems.

Power · Battery Chemistry

LFP

Lithium Iron Phosphate

4,500
Full cycles at 25 °C to 70 % SoH
Low runaway severity Stable chemistry Outdoor safe

NCA · Battery Chemistry

NCA

Nickel Cobalt Aluminum

~3,000
Cycles
~8 yr
Service life
High
Energy density
Active cooling req. Stationary use

Inside the Battery — LFP vs NCA

Cell Cross-Section — Cathode (+) Top · Anode (−) Bottom

LFP — Power
NCA — Other ESS
Li⁺ is the carrier ion — moves between cathode and anode through the electrolyte Anode (graphite) is identical in both LFP and NCA chemistries Cathode material determines safety, lifetime, and thermal stability

Cathode Crystal Structure — Where the Elements Live

LFP — Olivine Structure

LiFePO₄

Li Fe P O

Li sits in channels between FePO₄ layers. O is locked inside PO₄ tetrahedra — cannot escape, even above 270 °C.

NCA — Layered Oxide

LiNi₀.₈Co₀.₁₅Al₀.₀₅O₂

Li Ni Co Al O

Li alternates with Ni/Co/Al-O layers. O is held by weaker ionic bonds — releases above ~150 °C, igniting the electrolyte.

Battery Lifetime: LFP vs NCA

LFP (Windrose)
4,500 full cycles at 25 °C to 70 % state of health
NCA
~3,000 cycles — ~8 year service life

Windrose LFP pack: 4,500 full cycles at 25 °C to 70 % state of health (cell: over 6,000). NCA chemistry degrades faster under heavy daily cycling, typically reaching end-of-life around 8 years. LFP also releases far less heat and gas if a cell fails — a critical safety advantage for outdoor storage.

Contact sales

sales@windrose.ai